0

Sterile Garment Cabinet

Sterile Garment Cabinet
Product Description

Our organization, SN Global Technologies is counted amongst the top and renowned manufacturers, suppliers and exporters of premium grade Sterile Garments Cabinets.  These cabinets are used in laboratories, food processing units, aerospace manufacturing unit etc. for storing apparels worn in the clean room. The offered cabinets provide sterile environment that reduces the cross contamination of microorganisms. At our technologically advanced production set up, we make these sterile garment cabinets from quality assured raw materials in accordance to the set industry norms and standards.

Additional information:

 

  • These cabinets are equipped with the HEPA filters and UV germicidal
  • Constant airflow reduces the condensation
  • Available in different racks options

 

Technical specification

  • Supply Filter : Imported Mini pleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% for 0.30µ.
  • Return Air Pre-filter : Return Air Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5µ.
  • Fresh Air Filter : Fresh Air Filter Made from non-woven synthetic with HDPE mesh; conforms to EU 4 Grade, with an efficiency rating better than 90% down to 10µ.
  • Motor Alower Assembly : Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA.
  • Differential Pressure Gauge : Dwyer Make Magnehelic Gauge ( 0-25mm: 1 Nos.) to monitor pressure drop across HEPA.
  • Door : SS 304 double walled door construction with flush glass view panels with SS handles and SS hinges.
  • Shelves : SS 304 hanging arrangement (or) removable type shelves
  • ON / OFF Switches : SS ON / OFF Switches for motor & lights
  • Switch Socket: 6/15 Amp single-phase switch socket use for external equipment
  • DOP Port: DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test.
  • Electrical Supply: 230 AC 1-ø50 HZ / 415V AC 3-ø50HZ
  • Noise : Noise Level Less than 67 dB on scale 'A' when ambient is not greater than 55 dB on scale 'A'
  • Vibration Level : Minimum

 

Contact Us

Hira Hari Ind. Estate, Nr. Highway No.08, Gala No. 4, Industrial Estate, Pelhar, Vasai (E), Vasai, Maharashtra, 401208, India